Comments on: How I Built a Thermostat for NuHeat Floor https://blog.sergem.net/how-i-built-a-thermostat-for-nuheat-floor/ have to publish, sometimes Fri, 30 Jul 2021 22:33:43 +0000 hourly 1 https://wordpress.org/?v=6.1.6 By: admin https://blog.sergem.net/how-i-built-a-thermostat-for-nuheat-floor/#comment-476 Fri, 30 Jul 2021 22:33:43 +0000 http://blog.sergem.net/?p=274#comment-476 In reply to Trevor Green.

Thanks. Headless is the way to go, unless you require controls and display at the point of use, as Chromium on PI zero pretty sluggish. If you can put a double box into wall, all the better! (I could not)

]]>
By: Trevor Green https://blog.sergem.net/how-i-built-a-thermostat-for-nuheat-floor/#comment-475 Fri, 30 Jul 2021 21:05:53 +0000 http://blog.sergem.net/?p=274#comment-475 Very cool. I’m going to try something like this. Might go headless though and see about integrating this straight in to Home Assistant as I have 6 different pads and 6 controllers at present.

Perhaps a 2 gang box so there’s enough room for the relay/ADC/Pi zero/GFCI plug, just blind off the one Decora. Perhaps I can mate a small display to a Decora hole (even 3D print something) so there can be a local temp indicator.

Thoughts on that integration?

]]>